DASH-EMS
Field Survey App
Dash Environmental Monitoring Services (Pty) Ltd
Surveys
Select Survey Type
Client Information
Survey Details
Employee Information
Similar Exposure Groups (SEGs)
Previous Monitoring
Instrumentation
Noise Measurements
Add areas, then add multiple readings per area. The app auto-averages.
โ < 82 dB(A) | โ 82โ85 dB(A) | โ โฅ 85 dB(A)
Illumination Measurements
Add areas with lux readings. The app auto-checks against task-specific minimums.
โ Meets minimum | โ Below minimum
Indoor Air Quality
Record ambient first, then each indoor area. 4 parameters per location.
Ergonomics Assessment
Add each workstation or area. Tick risk factors, set risk score, add photos and notes.
RF1โRF8: Office workstation risks
RF9โRF12: Manual handling & posture
CF1โCF4: Cognitive & psychosocial risks
H&S: General health & safety observations
+ Positive remarks
Similar Exposure Groups (SEGs)
Lead Exposure Assessment
Add measurement areas. Select lead type to auto-fill OEL. Enter airborne concentrations.
Lead (inorganic): 0.15 mg/mยณ ยท Lead alkyls: 0.10 mg/mยณ
โฅ OEL โ Respirator Zone ยท โฅ ยฝ OEL โ Air Monitoring Required
HCA Exposure Monitoring
Add sampling points. Select chemical agent to auto-fill OEL. Enter measured concentrations.
≥ OEL → Non-compliant (immediate action) · ≥ ½ OEL → Action level (monitoring programme)
Auto-flags: ☣ Carcinogen · ✋ Skin notation · ⚕ Medical Surveillance · 🧪 BEI
Dust Exposure Monitoring
Add sample points. Select dust type to auto-fill OEL. Enter lab concentration results.
Inhalable (PNOS): 10 mg/m³ · Respirable (PNOS): 5 mg/m³
Silica (Quartz): 0.1 mg/m³ (R) · Wood Dust (hardwood): 2 mg/m³
≥ OEL → Non-compliant · ≥ ½ OEL → Action level
Chemical Storage & Compatibility Assessment
Inspect each chemical storage area. Assess GHS compliance, segregation, bunding, ventilation, signage and emergency equipment.
Heat Stress Assessment (WBGT)
Add measurement areas. Enter WBGT reading and select work rate to auto-determine compliance.
Light work: 33°C (accl.) / 32°C · Moderate: 30°C / 28°C · Heavy: 28°C / 25°C
Cold Stress Assessment
Add measurement areas. Enter air temperature and wind speed to assess cold stress risk.
>10°C No risk · 0–10°C Moderate · -1 to -17°C Cold · -18 to -34°C Very Cold · <-34°C Extreme
Ventilation Assessment
Add measurement points. Enter face/duct/capture velocity and compare against design specification.
Spray booth face velocity ≥ 0.5 m/s (SANS 1018 / OSHA 100 fpm)
LEV capture velocity: 0.5–2.5 m/s depending on type · ACGIH Industrial Ventilation Manual
Environmental Pollution Risk Assessment
Select applicable environmental media, then add findings per medium.
Environmental Noise Survey (SANS 10103)
Add measurement points. Select district type and time period to auto-determine SANS 10103 limits.
Rural: 45/35 · Suburban: 50/40 · Sub+roads: 55/45 · Urban: 60/50 · CBD: 65/55 · Industrial: 70/60
Interior Acoustic Survey (SANS 10103)
Add rooms/areas. Select room type to auto-determine SANS 10103 indoor noise rating limit.
Private office: 40 dBA · Open plan: 45 dBA · Boardroom: 35 dBA · Classroom: 35 dBA · Hospital ward: 30 dBA